Version 2.8.14 (Build No. 2.8.14.74)
Release|2021-12-15
New Features and Improvements
-
Supports a new device.
- Input Module (IM-120)
-
Face 1:N security level setting support for CoreStation.
-
Applied OpenJDK.
InfoAs of BioStar 2 version 2.8.14, OpenJDK is applied to allow users to use BioStar 2 regardless of the Java version installed on the PC.
-
Added Department, Title, and Telephone to User Column Settings.
-
Improved to be able to enter and modify PIN when using user CSV import.
-
Improved performance by no longer inquiring unnecessary user information when calling API.
-
Improved device search speed using API.
-
Improved Automatic User Synchronization performance.
-
Added missing indexes to database columns used for synchronization.
-
Improved 'All Devices' Automatic User Synchronization speed and fixed synchronization errors.
-
Improved 'Specific Devices' Automatic User Synchronization speed.
-
Improved to send changes in bulk when using 'Specific Devices' Automatic User Synchronization.
-
Added exception handling for null value when retrying after 'Specific Devices' Automatic User Synchronization failed.
-
-
Improved security vulnerabilities.
-
Applied Log4j 2 v2.16.0.
-
Applied OpenSSL 1.1.1k.
-
Applied jQuery 3.4.1.
-
Improved to check Operator Level and Custom Account Level when using API.
-
Fixed an issue where if the CSV export file contains a formula symbol
=
, the formula is applied when the file is executed. -
Improved to perform CORS check and security check for session ID when connecting to web socket.
-
Prevention for SQL Injection attack.
-
Improved to display error messages (error name, http error code, description) when a server status response error occurs.
-
-
Updated APIs in Swagger.
-
Updated the description of device Trigger and Action API.
-
Added Visual Face Image Upload API.
-
Fixed an issue where users were not added to the actual device differently from the result returned when adding users to devices using [POST] /devices/{id}/users or [POST] /api/users/export.
-
-
Improved event log processing performance.
-
Improved event log inquiry speed in MS SQL Server database environment.
-
Improved database processing speed when generating device event logs.
-
Fixed to update only devices with changes in the database when synchronizing device log data.
-
-
Improved the loading speed of the device menu when restarting the BioStar 2 server with multiple devices connected.
-
Improved device connection speed.
-
Improved performance dealing devices by increasing the default number of device threads.
-
Improved loading speed of the monitoring menu by deleting unnecessary check logic.
-
Improved access group link speed by deleting unnecessary codes.
-
Improved blacklist card synchronization speed.
-
Improved database data processing speed.
-
Improved server performance.
-
Improved to maintain the existing connection without reallocating the client port every time when communicating between the C server and the Java server.
-
Improved to prevent unnecessary function calls according to log level in C server.
-
Improved to reuse objects for encrypt personal data in Java server instead of reallocating them every time.
-
-
Improved the speed of querying registerable devices using API.
-
26 bit Wiegand card support for BioStar 1.x to BioStar 2.x Migration Tool.
-
Improved to check the database connection status before proceeding with the BioStar 2 installation.
- Removed 'Check the database connection' option from the custom installation process.
-
Improved to be able to run Swagger documents locally without a server address.
-
Changed the default value of Held Open.
-
Before: 3 seconds
-
After: 10 seconds
-
-
Changed the device icon of OM-120.
Bug Fixes
-
Even though the screen saver function is supported, the function was not displayed on the Settings of the X-Station 2 fingerprint model (XS2-ODPB, XS2-OAPB) Affects version: 2.8.12
-
When using the 'Specific Devices' Automatic User Synchronization option, it did not sync if the user ID contains some symbols
_
Affects version: 2.7.11. -
When using the 'Specific Devices' Automatic User Synchronization option, the synchronization logic operated as 'All Devices' when executing Write Smart Card Affects version: 2.7.11.
-
Chrome autocomplete function was mapped incorrectly in the information input field on the Add User screen Affects version: 2.7.8.
-
some languages were displayed as question marks in Audit Trail when using MS SQL Server database Affects version: 2.7.0.
-
When using the Visual Face as a user profile image, it exceeded the allowed size of the profile image and did not sync to devices Affects version: 2.8.6.
-
Fake Detection was set to 'Normal' instead of the default value (Secure) when resetting after disabling Fusion Matching Mode on FaceStation F2 Affects version: 2.6.0.
-
When setting the logo image as the home screen for FaceStation F2, the image was not applied in the correct resolution for the device Affects version: 2.8.6.
-
It was not possible to enter uppercase letters in the server address when using 'Device → Server Connection' Affects version: 2.7.0.
-
Custom user field data was not reflected in the T&A report Affects version: 2.8.3.
-
Fixed an issue where key values were exposed when fetching smart card layouts using API Affects version: 2.0.
-
The server crashed intermittently.
-
C server crash occurred when database inquiry failed while creating user group cache Affects version: 2.0.
-
Lock handling was missing in serviceTask JsonResult Affects version: 2.0.
-
-
Even after deletion, devices previously used for credential enrollment continued to display in the credential enroll device list Affects version: 2.0.
-
When BioStar 2 was newly installed and then launched, the migration screen was executed instead of the login screen Affects version: 2.4.0.
-
When running 'Manage Users in Device' by selecting a device that supports only cards, the status of the user with the enrolled fingerprint was displayed as 'Different' Affects version: 2.0.
-
When entering an email subject in a language with Unicode applied in the email settings, the text of the email subject was sent in a garbled state depending on the set SMTP server. Affects version: 2.0
-
When restoring a backed-up log table, if the log table index and the current log table were different and could not be matched, the table creation failed Affects version: 2.7.11.
-
When generating more than 10 events by selecting 'Input (Event Name Change)' in the Trigger & Action settings of CoreStation, it did not work properly Affects version: 2.8.8.
-
If there is a language not supported by BioStar 2 in the local storage language of the browser, it was not possible to enter the BioStar 2 login page Affects version: 2.0.
-
When creating a user group, an error code occurred on the browser and the user group was not created Affects version: 2.7.14.
-
When using server matching with FaceStation 2's authentication mode set to Card+Face, the face authentication mode did not work after card authentication Affects version: 2.8.6.
InfoThis modification will be applied to devices with firmware version 1.5.1 or later installed.
-
During 'All Devices' Automatic User Synchronization, the access group and door synchronization results were not updated intermittently Affects version: 2.0.
-
Devices were disconnected when the amount of data was large during Automatic User Synchronization Affects version: 2.0.
-
When adding a user using API, it was possible to create a user ID with a value not supported by BioStar 2 Affects version: 2.8.1.
-
When adding events by selecting 'Input (Event Name Change)' in the device's Trigger & Action settings, the 'Add Event Name' button was cut off if there were many registered events Affects version: 2.0.
-
When importing users with CSV import, 'Upload successful' message was displayed even if there was information that was not updated Affects version: 2.3.0.
-
When a device that does not support the intelligent slave sent OSDP ID as an invalid value, BioStar 2 initialized the value to 0, updating RS-485 settings and disconnecting the existing RS-485 connection Affects version: 2.8.10.
-
Even though the server matching is supported, the function was not displayed on the settings of BioStation 2 Affects version: 2.2.2.
-
When a user has abnormal profile image, the user sync process was not finished properly Affects version: 2.8.0.