Skip to main content

Version 2.9.0 (Build No. 2.9.0.80)

Release|2022-09-26

New Features and Improvements


  1. Supports BioStation 3

  2. Supports user information partial update

    • Supporting device: BioStation 3 v1.0.0
  3. Improved extraction of images used for visual face credentials

  4. Simplified visual mobile face enrollment process

  5. Supports visual face import

    • Enrolls visual face when file name of the image matches user ID
  6. Supports visual face migration

  7. Device added supporting Fingerprint LFD

    • Supporting device: BioLite N2 v1.5.0
  8. Improved door open logs

  9. Added logs to indicate full capacity on devices

  10. Improved security vulnerabilities

    • Improved Unquoted Service Path vulnerability

    • Improved Clickjacking vulnerability

    • Improved minor vulnerabilities

  11. CSV Improved error messages on CSV import fail

Bug Fixes


  1. QR/Barcode having the same card ID as a CSN or Wiegand card being authenticated while using 'Server matching' with X-Station 2 Affects version2.8.11

  2. Operator having privilege to edit users couldn't edit user information due to not having email setting view privilege Affects version2.8.14

  3. Event logs not getting stored in the database while 'Real-time Monitoring' displaying the logs Affects version2.8.6

  4. Visitor's fingerprint enrollment failing from 'Visitor' menu Affects version2.8.14

  5. BioStar 2 not running properly due to incorrect MSSQL table constraints Affects version2.8.5

  6. Requiring phone number, a non-required field, when issuing mobile access card via CSV import Affects version2.7.12

  7. Visual face not being synchronized to devices intermittently Affects version2.8.12

  8. Sending users to devices that doesn't need synchronization when another device fails on synchronization when using 'All Devices' as the option of 'Automatic User Synchronization' menu Affects version2.8.6

  9. Users not related to the action of 'Batch Edit' being synchronized to devices that belongs to the target of editing Affects version2.8.14

  10. BioStar 2 abnormally occupying memory when manually locking and releasing a door Affects version2.0.0

  11. Visual face enrollment page not showing any strings when the browser language is set to a language that the enrollment page does not support Affects version2.8.5

  12. BioStar 2 showing success as result when uploading a user having a card ID that already exists within BioStar 2 Affects version2.8.9

  13. Devices supporting 'Extended Auth Mode' intermittently not displaying auth modes correctly Affects version2.8.6

  14. BioStar 2 not finding the correct port when checking licenses Affects version2.7.11

  15. Unassigned 'Mobile Access Cards' being sorted in a descending order in BioStar 2 running with MariaDB Affects version2.8.7

  16. Video logs being recorded shorter than the configured settings Affects version2.5.0

  17. 'Mobile Access Card' issue page not following the 'Date Format' settings when its set as mm/dd/yyyy or dd/mm/yyyy Affects version2.8.9

  18. Export displaying expiry date on 'Mobile Access Cards' that does not have any expiry date Affects version2.8.9

  19. 'Enroll' and 'Search' buttons intermittently disappearing from 'Visitor' menu when enrolling a visitor Affects version2.8.7

  20. Error message indicating the maximum number of face credentials displaying incorrect numbers Affects version2.8.6

  21. BioStar 2 API Swagger not displaying Unicode characters for response Affects version2.8.14

  22. 'Mobile Access Cards' only being issued for 100 cards when the CSV contains more than 100 Affects version2.7.12

  23. Result of the 'Muster Status' on print and CSV having different time zones Affects version2.8.6

  24. Wiegand card ID accepting only 32 characters when is should accept to 78 characters Affects version2.7.12

  25. Authentication succeeding when the authentication failed to pass the global 'Anti-passback' check Affects version2.8.11

  26. X-Station 2 firmware files not displaying correctly on the firmware upgrade page Affects version2.8.12

  27. Image and video logs not being displayed when accessing 'Monitoring' menu without accessing 'Video' menu Affects version2.7.0

  28. Event logs not displaying when a custom operator sets a filter from 'Event Log' menu having more than 1,000 user groups Affects version2.8.3

  29. Video logs not being displayed when accessing BioStar 2 using a domain URL Affects version2.6.0

  30. Card not being able to re-used as an arm/disarm card or assigning to a user when the card was registered as an arm/disarm card for an 'Intrusion Alarm Zone' and the zone itself gets deleted Affects version2.5.0