Skip to main content

Version 2.9.0 (Build No. 2.9.0.80)

Release|2022-09-26

New Features and Improvements​


  1. Supports BioStation 3

  2. Supports user information partial update

    • Supporting device: BioStation 3 v1.0.0
  3. Improved extraction of images used for visual face credentials

  4. Simplified visual mobile face enrollment process

  5. Supports visual face import

    • Enrolls visual face when file name of the image matches user ID
  6. Supports visual face migration

  7. Device added supporting Fingerprint LFD

    • Supporting device: BioLite N2 v1.5.0
  8. Improved door open logs

  9. Added logs to indicate full capacity on devices

  10. Improved security vulnerabilities

    • Improved Unquoted Service Path vulnerability

    • Improved Clickjacking vulnerability

    • Improved minor vulnerabilities

  11. CSV Improved error messages on CSV import fail

Bug Fixes​


  1. QR/Barcode having the same card ID as a CSN or Wiegand card being authenticated while using 'Server matching' with X-Station 2 Affects version: 2.8.11

  2. Operator having privilege to edit users couldn't edit user information due to not having email setting view privilege Affects version: 2.8.14

  3. Event logs not getting stored in the database while 'Real-time Monitoring' displaying the logs Affects version: 2.8.6

  4. Visitor's fingerprint enrollment failing from 'Visitor' menu Affects version: 2.8.14

  5. BioStar 2 not running properly due to incorrect MSSQL table constraints Affects version: 2.8.5

  6. Requiring phone number, a non-required field, when issuing mobile access card via CSV import Affects version: 2.7.12

  7. Visual face not being synchronized to devices intermittently Affects version: 2.8.12

  8. Sending users to devices that doesn't need synchronization when another device fails on synchronization when using 'All Devices' as the option of 'Automatic User Synchronization' menu Affects version: 2.8.6

  9. Users not related to the action of 'Batch Edit' being synchronized to devices that belongs to the target of editing Affects version: 2.8.14

  10. BioStar 2 abnormally occupying memory when manually locking and releasing a door Affects version: 2.0.0

  11. Visual face enrollment page not showing any strings when the browser language is set to a language that the enrollment page does not support Affects version: 2.8.5

  12. BioStar 2 showing success as result when uploading a user having a card ID that already exists within BioStar 2 Affects version: 2.8.9

  13. Devices supporting 'Extended Auth Mode' intermittently not displaying auth modes correctly Affects version: 2.8.6

  14. BioStar 2 not finding the correct port when checking licenses Affects version: 2.7.11

  15. Unassigned 'Mobile Access Cards' being sorted in a descending order in BioStar 2 running with MariaDB Affects version: 2.8.7

  16. Video logs being recorded shorter than the configured settings Affects version: 2.5.0

  17. 'Mobile Access Card' issue page not following the 'Date Format' settings when its set as mm/dd/yyyy or dd/mm/yyyy Affects version: 2.8.9

  18. Export displaying expiry date on 'Mobile Access Cards' that does not have any expiry date Affects version: 2.8.9

  19. 'Enroll' and 'Search' buttons intermittently disappearing from 'Visitor' menu when enrolling a visitor Affects version: 2.8.7

  20. Error message indicating the maximum number of face credentials displaying incorrect numbers Affects version: 2.8.6

  21. BioStar 2 API Swagger not displaying Unicode characters for response Affects version: 2.8.14

  22. 'Mobile Access Cards' only being issued for 100 cards when the CSV contains more than 100 Affects version: 2.7.12

  23. Result of the 'Muster Status' on print and CSV having different time zones Affects version: 2.8.6

  24. Wiegand card ID accepting only 32 characters when is should accept to 78 characters Affects version: 2.7.12

  25. Authentication succeeding when the authentication failed to pass the global 'Anti-passback' check Affects version: 2.8.11

  26. X-Station 2 firmware files not displaying correctly on the firmware upgrade page Affects version: 2.8.12

  27. Image and video logs not being displayed when accessing 'Monitoring' menu without accessing 'Video' menu Affects version: 2.7.0

  28. Event logs not displaying when a custom operator sets a filter from 'Event Log' menu having more than 1,000 user groups Affects version: 2.8.3

  29. Video logs not being displayed when accessing BioStar 2 using a domain URL Affects version: 2.6.0

  30. Card not being able to re-used as an arm/disarm card or assigning to a user when the card was registered as an arm/disarm card for an 'Intrusion Alarm Zone' and the zone itself gets deleted Affects version: 2.5.0