How to Set Up the Timed Anti Passback
Timed Anti PassBack restricts frequent entries by setting an initialization time for anti-passback. This feature prevents users from re-authenticating with the same device immediately after access authentication, ensuring a defined period must elapse before re-authentication is possible.
Timed Anti PassBack can be used without a separate BioStar 2 license.
Setting Timed Anti PassBack on the Door
-
Click DOOR.
-
Click ADD DOOR and set Information, Configuration, Option, etc.
The image above is an example screen and may differ from the actual screen. Info-
If the door is set up with a wireless door lock, Timed Anti PassBack cannot be used.
-
Timed Anti PassBack can only be set when Entry Device or Exit Device and Door Relay are selected.
-
Since this feature is used to enhance door security, it can be set even when one of the Entry Device or Exit Device is selected.
-
-
Timed Anti PassBack and Use sensor when Entry Confirmed APB enabled features cannot be used at the same time.
-
Timed Anti PassBack and Anti PassBack features cannot be used at the same time.
-
-
Set Timed Anti PassBack to Use and enter the desired reset time.
The image above is an example screen and may differ from the actual screen. - Reset Time: The input unit is in minutes (min.), with a default setting of 10 minutes. Users can input a time within the range of 0 to 60 minutes.
InfoIf Reset Time is set to 0 minutes, Timed Anti PassBack will not operate.
-
Click Apply to save the settings.
If Timed Anti PassBack occurs after setup, you can check the event and Image Log in the MONITORING menu.