Firmware Version 1.2.3 (Build No. 1.2.3_210518)

Release|2021-05-24

New Features and Improvements


  1. Upgraded to the 1.1.1i version of OpenSSL.

  2. Intelligent Slave Support

    • Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller.
  3. The transmission power level for Bluetooth Low Energy (BLE) has been adjusted.

Bug Fixes


  1. If 31 slave devices were connected and one of the devices got disconnected, the master device rebooted. Versión afectada1.0.0

  2. Incorrect BitCount was sent if a user authenticated with AoC when the device was connected to a 3rd-party system via OSDP. Versión afectada1.0.0

  3. When using a static IP while the DNS server address was configured, a reboot on the device caused communication problems between the server and the device. Versión afectada1.0.0

  4. It failed to reconnect to the slave device after downgrading its firmware version to 1.1.0. Versión afectada1.0.0

  5. Device responded that it supported transparent mode by OSDP_PDCAP when connecting as a slave while it did not support it. Versión afectada1.0.0

  6. When calling the BS2_ResetConfigExceptNetInfo API from the BioStar Device SDK, a 'Timeout' error occurred. Versión afectada1.0.0

  7. The OSDP LED Temporary command did not work properly. Versión afectada1.0.0

  8. The network reset on the first use was needed to use OSDP default keys to communicate. (for devices released with the firmware version 1.2.0 or later) Versión afectada1.2.0

  9. It was able to communicate using default keys after changing the key settings when the device was connected to a 3rd-party device via OSDP. Versión afectada1.0.0

  10. Secure communication was not available by using the default key after downgrading firmware to version 1.1.0 or below which does not support encryption. Versión afectada1.2.0