本文へスキップ

Firmware Version 1.4.1 (Build No. 1.4.1_210511)

Release|2021-06-01

New Features and Improvements


  1. Upgraded to the 1.1.1i version of OpenSSL.

  2. Intelligent Slave Support

    • Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller.
  3. Separated event logs of Mobile Access cards and RFID cards.

Bug Fixes


  1. When calling the BS2_ResetConfigExceptNetInfo API from the BioStar Device SDK, a 'Timeout' error occurred. 発生バージョン1.0.0

  2. Card data were output with the wrong BitCount while the device was communicating with a 3rd party controller via OSDP. 発生バージョン1.0.0

  3. When using a static IP while DNS server address was configured, a reboot on the device caused communication problems between the server. 発生バージョン1.0.0

  4. While the device was communicating with a 3rd party controller via OSDP, the device connected as a slave responded that it supported transparent mode by OSDP_PDCAP even though it did not actually support that mode. 発生バージョン1.0.0

  5. If 31 slave devices were connected and one of the devices got disconnected, the master device rebooted. 発生バージョン1.0.0

  6. Fingerprint authentication did not work after downgrading from firmware version 1.4.0 to firmware version 1.2.1. 発生バージョン1.4.0

  7. It was not able to communicate with a 3rd-party controller via OSDP with the default key before network initialization. (only for devices released with the firmware version 1.4.0 or later) 発生バージョン1.4.0

  8. It was able to communicate using default keys after changing the key settings when the device was connected to a 3rd-party device via OSDP. 発生バージョン1.3.0

  9. After initializing the slave device's settings, it was not able to connect it to a 3rd-party controller. 発生バージョン1.0.0

  10. Secure communication was not available by using the default key after downgrading firmware to version 1.3.1 or below which does not support encryption. 発生バージョン1.4.0