Firmware Version 1.5.0 (Build No. 1.5.0_220621)
Release|2022-06-21
Devices with the new BLE chip and the SE processor cannot downgrade to a lower version after upgrading the firmware to v1.5.0 or higher. Devices with existing BLE chips and SE processor can be downgraded to a lower version.
For more information, check the serial number of the device and contact the Suprema.
New Features and Improvements
-
Added new models that do not support BLE (Bluetooth Low Energy).
- BLN2-OA, BLN2-OD
-
Supports setting the byte order for smart cards.
- Supports setting the byte order of data to be output to Wiegand or OSDP.
-
Supports a new BLE (Bluetooth Low Energy) chip.
- The BLE chip parts of the hardware have been changed, and the firmware has been upgraded to be compatible with both the existing and new BLE chips.
-
Supports the dual SE processor.
-
Separated the log related to the cause of the door unlock.
-
Door open request by exit button
-
Door open request by operator
-
-
Added relay deactivation option for exit button input.
- Added the option to set the door open request log to occur but the relay not to operate when the exit button is pressed.
-
Supports Live Finger Detection.
Bug Fixes
-
Mobile card authentication suddenly does not work 発生バージョン: 1.3.2.
-
Global APB behavior for the same input was different depending on firmware version 発生バージョン: 1.4.0.
-
Device does not connect to a 3rd party controller (Software House iSTAR Edge G2) via OSDP 発生バージョン: 1.4.1.
-
When changing the intelligent slave settings on the detailed page of the device on BioStar 2, the settings were not applied 発生バージョン: 1.4.2.
-
Migration malfunction occurs when the firmware is upgraded from v1.2.0 or earlier to v1.3.0 or higher 発生バージョン: 1.3.0.
- Migration did not complete and the device boots to the main screen, some keys do not work or an abnormal screen is displayed.
-
When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Input Status Request command while the input port is grounded 発生バージョン: 1.4.1.
-
When communicating with a 3rd party control panel via OSDP, the device does not respond to the Output Status Report command while the relay reacts to it 発生バージョン: 1.4.1.
-
When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Output Status Request command while the relay status is 'On' 発生バージョン: 1.4.1.
-
Device does not recognize certain HID iCLASS Seos cards 発生バージョン: 1.0.0.