Firmware Version 1.0.1 (Build No. 1.0.1_221020)
Release|2022-10-21
New Features and Improvements
-
Improved motion detection performance for low-light environments.
-
Improved Visual Face matching algorithm.
-
Improved all pop-up messages displayed on the device to operate according to the time set in Message Timeout.
-
Fixed Korean and English strings in the RTSP menu.
Bug Fixes
-
When upgrading resources or firmware from BioStar 2, the device could not check the progress of the upgrade because no information was displayed. 発生バージョン: 1.0.0
-
When synchronizing multiple users to a device in BioStar 2 and then restarting the device, the User Usage on the device displays a different number of visual faces than the number of synchronized. 発生バージョン: 1.0.0
-
When entering the device detail page after adding a logo image to the device connected as a slave, an Invalid payload error occurs and the RS-485 get disconnected. 発生バージョン: 1.0.0
-
When Device Hashkey Management is set to Use in BioStar 2 and migration proceeds, all users are deleted from the device, but a delete notification pop-up is not displayed. 発生バージョン: 1.0.0
-
Device hangs intermittently and then restarts. 発生バージョン: 1.0.0
-
When entering the Wireless, the new SSID does not appear, but only the previously searched SSID appears. 発生バージョン: 1.0.0
-
When enrolling a visual face or card on a device using the BioStar 2, the scan screen is not visible and the screen saver state remains. 発生バージョン: 1.0.0
-
When the call button on the main screen is pressed with only one extension number stored in the device, it does not connect directly. 発生バージョン: 1.0.0
-
In Edit User, if you select Extended Private Auth Mode as ID + Fingerprint/PIN and press OK, the fingerprint icon is incorrectly displayed as a face icon in the Extended Private Auth Mode list. 発生バージョン: 1.0.0
-
Authentication failure occurs when authenticating with AoC with private auth mode set to Card + Face. 発生バージョン: 1.0.0
-
When the device is restarted via BioStar 2, only a notification sound plays and the restart pop-up message does not appear. 発生バージョン: 1.0.0
-
Firmware upgrade via USB restarts the device without a success or failure popup message. 発生バージョン: 1.0.0
-
In BioStar 2's T&A menu, the Schedule display part is blank when creating a T&A Code with a Schedule other than Always and selecting the T&A Code on the device. 発生バージョン: 1.0.0
-
Memory usage incorrectly displayed in DRAM Usage in Memory Info. 発生バージョン: 1.0.0
-
When entering the menu from a device connected as a slave, a normal menu touch sound plays instead of a warning sound. 発生バージョン: 1.0.0
-
When enrolling a visual face in the USER menu in BioStar 2, when the scan waiting time exceeded while enrolling the 1st face and then scanning the 2nd face, the face enrolled in the 1st appears. 発生バージョン: 1.0.0
-
If the network is connected to a wireless LAN and then enters Wireless again after changing to an ethernet connection, the wireless AP list is not displayed. 発生バージョン: 1.0.0
-
Device hangs intermittently when Wiegand Input/Output setting is set to Output. 発生バージョン: 1.0.0
-
Extension number gets stored in the phonebook while exceeding the maximum characters in the Display Name of the Intercom settings. 発生バージョン: 1.0.0
-
When entering the edit screen by selecting the Auth Mode set in the device's Auth Mode, the touch sound does not play. 発生バージョン: 1.0.0
-
Device connected as a slave intermittently operates while disconnected. 発生バージョン: 1.0.0
-
An error occurs when calling the extension number when the Intercom of the device is set to Not Use via BioStar 2 while the list of extension numbers is displayed by pressing the call button on the main screen of the device. 発生バージョン: 1.0.0
-
In the screen to set the Schedule in Auth Mode, the already created schedule is shown as a duplicate. 発生バージョン: 1.0.0
-
When the device is in the middle of Factory Default process, the device hangs while loading. 発生バージョン: 1.0.0
-
When the Language of the device is set to Custom, the Voice Instruction menu part of Sound displays as a blank. 発生バージョン: 1.0.0
-
When the Time Zone of the master device connected via RS-485 is changed, the Time Zone of the slave device does not change. 発生バージョン: 1.0.0
-
When authenticating with a mobile card set to NFC, authentication fails and the device restarts intermittently 発生バージョン: 1.0.0
-
The correct message does not appear when an unenrolled card is scanned with Filter set to Card in the user search 発生バージョン: 1.0.0
-
The pop-up to set the Filter on the EVENT LOG search screen does not disappear even after the time set in the device's Menu Timeout has elapsed. 発生バージョン: 1.0.0
-
Event log is not logged when Time Zone is changed on the device. 発生バージョン: 1.0.0
-
When scanning Visual Face via BioStar 2 while the device is in the SETTINGS, the scan screen does not close on the device even after scanning is complete. 発生バージョン: 1.0.0
-
Baud Rate selection pop-up appears when touching an empty space at the bottom of the Ethernet screen. 発生バージョン: 1.0.0
-
When sending a user whose card is duplicated with another user from BioStar 2 to the device, the user is deleted from the device. 発生バージョン: 1.0.0
-
When the firmware is upgraded for each device connected as master-slave, the slave device completes normally, but the master device hangs. 発生バージョン: 1.0.0
-
RTSP connection termination event log is not logged and RTSP icon is not deleted even after setting RTSP to Not Use. 発生バージョン: 1.0.0
-
Does not restart on Restore Default due to setup error. 発生バージョン: 1.0.0
-
Date & Time not displayed correctly. 発生バージョン: 1.0.0
-
When adding a user, the backlight does not turn off when waiting without card input on the card scan screen. 発生バージョン: 1.0.0
-
Search does not work when searching by Start Time and End Time in EVENT LOG. 発生バージョン: 1.0.0
-
An incorrect schedule displays in the Edit Auth Mode. 発生バージョン: 1.0.0
-
If you scan a Wiegand format card that is not set when enrolling a card to a user and then scan a normal card, it will not be scanned. 発生バージョン: 1.0.0
-
The device retains the call screen even after the recipient terminates the call. 発生バージョン: 1.0.0
-
WiFi MAC does not appear in DASHBOARD and Device Info for Wi-Fi supported models. 発生バージョン: 1.0.0
-
On the scan card screen, the background allows touch and the face can get authenticated. 発生バージョン: 1.0.0
-
When enrolling a card in BioStar 2, after selecting Write Smart Card, the device restarts while waiting for scan. 発生バージョン: 1.0.0
-
An issue occurs when upgrading the firmware of a slave device from BioStar 2 while the device is connected as Master-Slave. 発生バージョン: 1.0.0
-
Slave device disconnects and the firmware upgrade fails.
-
Master device restart fails.
-
-
The OK button does not work when repeatedly searching the EVENT LOG. 発生バージョン: 1.0.0
-
Intermittently, the image log is logged abnormally. 発生バージョン: 1.0.0
-
Speaker turns on and off repeatedly when multiple sound files are played continuously. 発生バージョン: 1.0.0
-
The device restarts abnormally when the firmware is upgraded while the device is locked. 発生バージョン: 1.0.0
-
Wireless connection intermittently disconnects when sending Visual face from BioStar 2 to device. 発生バージョン: 1.0.0
-
The screen turns off at the time set in Menu Timeout during an Intercom call. 発生バージョン: 1.0.0
-
When deleting all logs, image logs does not get deleted. 発生バージョン: 1.0.0
-
VFMCore version information is not displayed when long-touching the MAC in Device Info. 発生バージョン: 1.0.0
-
When issuing a Smart Card, if a fingerprint/face is included in Private Auth Mode, the issuance fails intermittently in a specific card. 発生バージョン: 1.0.0