Firmware Version 1.5.0 (Build No. 1.5.0_210628)

Release|2021-07-08

Main Fixes

  1. Incorrect temperature was displayed when authenticating from a slave device with the thermal camera. 発生バージョン1.4.0, 1.4.1, 1.4.2

New Features and Improvements


  1. Occupancy limit zone support

  2. Added support for the option to toggle Screen Saver for slave devices.

  3. Improved manually turning the secure tamper on or off even when the default hash key is set.

  4. Separated event logs of Mobile Access cards and RFID cards.

  5. Improved that the thermal camera works first when both the thermal camera and Wiegand bypass are set.

  6. Changed to a new touch pad

    • For devices with firmware version 1.4.2 or earlier, please follow the instructions below when replacing the front cover (touch pad).

      • Replace the front cover after upgrading the firmware to version 1.5.0 or later.

      • If you have already replaced the front cover before upgrading the firmware to version 1.5.0 or later, please upgrade to the latest version firmware again.

Bug Fixes


  1. The RS-485 communication did not work properly when connecting the device to a third-party controller after activating the Secure Communication mode. 発生バージョン1.4.2 or earlier

  2. A large number of 'Door closed' logs occurred abnormally when the door sensor was set to the input port of Secure I/O 2 connected as a slave device.

  3. Added defensive code to initialize if an error in the IR LED value occurs. 発生バージョン1.3.0 or earlier

  4. The screen was abnormally displayed when the second user authentication was successful on a slave device with dual authentication. 発生バージョン1.4.2 or earlier

  5. An abnormal event log occurred when the temperature measurement failed after setting the temperature mode to 'Temperature Check Before Authentication'. 発生バージョン1.4.0, 1.4.1, 1.4.2

  6. An abnormal event log occurred when measuring temperature after setting the temperature mode to 'Check Temperature Only'. 発生バージョン1.4.0, 1.4.1, 1.4.2

  7. The changed settings were reflected in the log but were not displayed properly on the screen when the time and attendance code settings were changed. 発生バージョン1.4.2 or earlier

  8. The relay operated as Off (Lock) after setting the scheduled unlock zone in the elevator and rebooting the master device. 発生バージョン1.4.2 or earlier

  9. The performed action, such as temperature output, was different from the intended action responding to the input signal set in the Trigger & Action feature when using the Suprema Thermal Camera. 発生バージョン1.4.0, 1.4.1, 1.4.2

  10. An issue of Suprema Thermal Camera screen being maintained even when the thermal imaging camera was toggled from 'Enabled' to 'Disabled'. 発生バージョン1.4.0, 1.4.1, 1.4.2

  11. The device abnormally terminated when establishing a communication connection with 'Device → Server'. 発生バージョン1.4.2 or earlier

  12. All files in the database were deleted after exporting them to a USB. 発生バージョン1.4.2 or earlier

  13. The slave device rebooted abnormally. 発生バージョン1.4.2 or earlier

  14. The RS-485 disconnection log continuously occurred when Secure I/O 2 was connected. 発生バージョン1.4.2 or earlier

  15. Ten administrators were still not deleted from the device when initializing the device that has 1,000 assigned administrators. 発生バージョン1.4.2 or earlier

  16. Device registration using Mobile Access app does not work on dynamic sites. 発生バージョン1.4.2 or earlier

  17. The Wiegand reader operated as Unlock after setting the Wiegand reader connected to DM-20 to Lock and rebooting the device when using the device with DM-20. 発生バージョン1.4.2 or earlier

  18. When enrolling a new fingerprint to AoC, it was able to authenticate the user with both the new fingerprint data and the existing fingerprint data. 発生バージョン1.4.2 or earlier

  19. The door relay status was not displayed properly when rebooting the master device while Manual Lock or Manual Unlock was set. 発生バージョン1.4.2 or earlier